Design your pipeline

The board file says what your hardware is. The pipeline says what to do with it: which devices produce readings, what happens to those readings on the way through, and what a cell is allowed to see and change. If the board file is the parts list, the pipeline is the instructions.

Unlike the board file, the pipeline is portable. It names devices, not pins, so the same pipeline runs against any board whose devices match.

Four parts, and one idea

A pipeline has four kinds of entry:

Sources turn a device into a stream of readings. Steps do something to a reading on the way past. Taps are the values a cell can read. Outlets are the values a cell can write.

One source reading feeding a tap directly, a moving-average step, and a cadence and fan-curve chain that drives an outlet

The idea that connects them is that everything you declare has a name, and you wire things together by naming them. There are three forms a reference can take:

ReferenceMeans
room_environment.temperaturean output of the source room_environment
temp_cadencethe output of the step temp_cadence
relay_cmd.contacta feedback-capable outlet's read-back of its real state

Wherever a pipeline asks for an input, a source or a tap's origin, it accepts one of those three. The first two are in the diagram above; the third is not, because it only exists for an outlet whose device can read its own state back: such an outlet publishes that read-back as a value, and the feedback section later on this page shows one. An outlet also exposes .error in the same form, carrying faults rather than a reading.

Sources

A source binds a device from your board file and says how to run it.

sources:
- id: room_environment
device: bme280
config:
sample_interval_ms: 1000
osrs_t: X4
filter: X4

device has to match a device id in the board file, and id is the name you will use to refer to this source's readings. They need not be the same, and room_environment says more downstream than bme280 does.

Everything under config is a setting the driver marked as belonging to the application: how often to sample, how much to oversample, how hard to filter. Settings fixed by the hardware, like the device's address, are not here. They are in the board file, and putting one in the wrong place is an error rather than a preference.

Steps

A step takes one input, does something, and produces an output under its own name.

steps:
- id: avg_temp
op: moving-average
input: room_environment.temperature
config:
window: 8

op names the step module. The ones used here are examples rather than the whole set, which the step reference lists in full. A step has exactly one input, which keeps the wiring easy to follow, and you build longer chains by pointing one step at another:

- id: temp_cadence
op: cadence
input: room_environment.temperature
config:
every: 4
mode: SampleHold

- id: fan_control
op: fan-curve
input: temp_cadence
config:
in_min: 25.0
in_max: 40.0
out_min: 0.0
out_max: 1.0

Chains may fan out. Several steps can take the same input, so one cadenced temperature can feed a fan curve and a threshold controller at once. What they may not do is form a loop: the generator sorts the step graph and rejects a cycle, naming the steps involved.

The wiring is type-checked. If a step expects an f32 and you feed it something else, you get told which step, which input and which types, before anything is built.

Two places to control the rate

A source has a sampling interval, and cadence can thin a path further downstream. It looks like duplication and it is not: the source rate is one decision, and each branch after a fan-out can make its own.

That is the reason the two exist. A pipeline might sample every 500 ms because a cell wants temperature that fresh, while a controller on the same reading only needs to recompute every couple of seconds. Setting the source slower would degrade the cell's view; cadencing the controller's branch costs the cell nothing.

A second reason follows from it: filters need samples to work with. A moving-average over eight samples is only meaningful if samples arrive often enough for eight of them to describe something. Sampling fast and thinning afterwards keeps that true.

A step may also produce nothing for a while. A moving average has no answer until its window fills. When a step yields nothing, whatever it feeds simply is not updated, and a tap downstream of it keeps whatever it held before, and holds nothing at all the first time round. That differs from a failed sensor, where the pipeline actively clears the tap.

Taps

A tap publishes a value under a name a cell can look up.

taps:
- name: temperature
kind: retained
type: f32
source: room_environment.temperature

- name: avg_temperature
kind: retained
type: f32
source: avg_temp

source is any of the three reference forms, so a tap can publish a raw driver output, the result of a step, or an outlet's read-back.

There are two kinds you will use. A retained tap holds the latest value with its timestamp, and reading it does not consume it, which is what you want for a measurement that is simply true right now. An event tap is a queue of things that happened, which the reader drains, and is what you want for alarms and state changes where missing one matters.

A third kind, batch, appears in the format but is reserved for planned work. It is not quietly ignored: declaring one fails generation with batch taps not yet supported by codegen.

Taps are your cell-facing interface, so choose them deliberately rather than exhaustively. Publish what a cell will actually use. Intermediate values inside a chain do not need to be taps just because they exist, though tapping one is a reasonable way to make a decision visible when you want to see why it was taken.

Outlets

An outlet is a value a cell can write, wired to a device that can act on it.

outlets:
- name: heat_relay
type: DigitalState
device: relay1

type is the value type the device's driver accepts, DigitalState for an on/off output and PwmDuty for a duty fraction, and it is checked against the driver rather than trusted. A device can be driven by exactly one outlet, so there is never a question of who is writing to it.

Outlets report their own failures. Any outlet exposes an error event you can tap, which is how a cell finds out that a write did not take effect:

taps:
- name: relay_fault
kind: event
type: OutletFault
source: heat_relay.error

A device wired with a feedback line offers more. Its driver reads the real state back on a separate input, and that read-back is available as a tap source too. It has to be an outlet on a feedback-capable device, so here it is a second outlet on a different relay:

outlets:
- name: relay_cmd
type: DigitalState
device: relay_fb

taps:
- name: relay_contact
kind: retained
type: bool
source: relay_cmd.contact

contact is a genuine read of the feedback line rather than an echo of the last write, which is the whole point of a hybrid driver. Ask a plain output for it and generation fails with driver declares no status output 'contact'.

Deciding where control lives

An outlet can also be driven from inside the pipeline, by giving it an input:

outlets:
- name: fan_speed
type: PwmDuty
device: fan1
input: fan_control

Now the fan curve drives the fan directly and no cell is involved. The same job could be done by a cell reading a temperature tap and writing fan_speed itself, so the interesting question is which to choose.

Put the decision in the pipeline when it has to be as fast as possible, or has to keep working regardless of any cell. Pipeline logic runs whether a cell is loaded, being replaced, or has crashed, and it does not wait for anything outside the layer.

Put the decision in a cell when it is a higher-level one, or when it needs something only a cell has: the network, BLE, other devices in the swarm, or history beyond the reading in front of it.

The short version is reflexes in the pipeline, judgement in the cell. A reflex consults nothing and must not stop; a judgement weighs context and can afford to be reloaded.

This is about behaviour and independence, not about safety. The Signal Layer makes no safety guarantees, and in-layer control should not be chosen on the belief that it does.

Closing the loop

Loops are allowed and useful, in more than one shape.

The ordinary one goes through the physical world: an outlet changes something, a sensor notices, and the next reading reflects it. Nothing in the pipeline is circular here, so nothing objects.

A tighter one goes through an outlet's read-back. Where a device reports its real state, as relay_cmd.contact does, a step can consume that and act on it.

Be careful here: a step whose input does not resolve is not reported. It is dropped from the generated pipeline silently, so a typo, or a status field the driver does not have, costs you the step without an error.

What is not allowed is a cycle among steps. That is caught during generation, because a step graph that loops has no order to run in.

What the generator checks

Most mistakes in a pipeline are caught before anything is built, and the messages name the entry at fault: a source pointing at a device the board does not have, a reference that resolves to nothing, a type mismatch between what a step wants and what feeds it, an outlet whose value type the driver does not accept, two outlets on one device, duplicate names, a cycle in the step graph, an application setting that belongs in the board file.

What it cannot check is intent. Nothing will tell you that a threshold is wrong for your room or that you cadenced away resolution a controller needed. For that, run it and watch.